中文摘要
节点导纳模型(NAM)行列式零点已被用于分析高渗透率变流器电力系统的稳定性,但传统NAM依赖各变流器动态相位且忽略频率耦合效应。本文提出统一的αβ坐标系下复数NAM,可集成不同变流器与无源元件,构建复杂系统的s域模型,并从物理角度揭示αβ复数NAM、dq域NAM与序域NAM的内在联系。该模型仅依赖节点电压初相位,准确反映频率耦合特性。考虑频率耦合后,验证了αβ复数NAM行列式零点与状态空间模型特征值的一致性。最后通过含多种变流器的三机系统验证了所提建模方法与稳定性判据的有效性,并揭示了构网型变流器布点与容量对系统稳定性的影响。
English Abstract
The zero points of the determinant of the node admittance model (NAM) have been applied to address the stability issues in power systems with high-penetration converters. Yet, the NAM generally relies on the rotations, i.e., the dynamic phase of each converter, moreover, the frequency coupling effect is neglected via NAM. To fill this gap, this paper presents the concept of a unified αβ-frame complex-valued NAM, with which different converters as well as the passive components can be incorporated to form an s-domain model for a complex system. Additionally, the intrinsic relationship among the αβ-frame complex-valued NAM, the dq-frame NAM, and the sequence-domain NAM is revealed from a physical perspective. The proposed model merely relies on the initial phase of the voltage at each node and accurately reflects the frequency coupling effect. Furthermore, considering the frequency coupling, the consistency between the zero points of the determinant of αβ-frame complex-valued NAM and the eigenvalues derived from the state-space model is demonstrated. Finally, the effectiveness of the modeling approach and stability criterion is validated by applying them to the 3-machine system with different types of converters. Besides, the effect of the placement and capacity of converters based on grid-forming control on the stability performance in the multi-converter system is revealed.
S
SunView 深度解读
该复数节点导纳建模方法对阳光电源多变流器并联系统具有重要应用价值。在PowerTitan大型储能系统中,多台ST系列储能变流器并联运行时,传统分析方法难以准确评估系统稳定性。该方法通过统一αβ坐标系建模,可精确分析构网型GFM与跟网型GFL变流器混合组网的频率耦合特性,为阳光电源优化构网型变流器布点策略、容量配置提供理论依据。特别适用于光储融合电站中SG光伏逆变器与ST储能变流器协同控制的稳定性校核,简化多机系统调试流程。该建模思路可集成到iSolarCloud平台的数字孪生功能,实现大规模新能源场站的稳定性预评估与智能诊断,提升系统可靠性与并网性能。