中文摘要

随着可再生能源和单相负荷的大量接入,低压配电网中三相不平衡及变压器轻/重载运行问题日益突出。现有互联低压配电网(ISLDN)研究较少同时兼顾上述两类问题的综合调控。为此,本文提出一种基于四桥臂软开点(F-SOP)的综合控制策略。首先建立包含F-SOP与变压器的系统综合损耗模型,揭示不平衡度与负载率对设备效率的影响;其次,以最小化网络损耗为目标,提出计及三相不平衡约束与经济运行区间的优化调度方法,生成F-SOP的功率指令;进一步设计改进的对等控制策略,确保优化调度实施并提升系统稳定性。仿真与实验验证了所提策略的有效性与可行性,结果表明该策略可显著降低日均损耗达62%,有效提升系统运行的经济性与可靠性。

English Abstract

With the increasing integration of renewable energy sources (RES) and single-phase loads, three-phase imbalance and transformer lightly/heavily loaded operation issues has become more prominent in low-voltage distribution networks (LDN). However, existing research on interconnected systems of LDN (ISLDN) rarely addresses the comprehensive management of both three-phase imbalance and lightly/heavily loaded operation issues. To this end, a comprehensive control strategy for three-phase imbalance and lightly/heavily loaded operation in ISLDN based on a four-leg soft open point (F-SOP) is proposed in this paper. Firstly, the comprehensive loss characteristics model of ISLDN including the F-SOP and the transformer are established, revealing that both imbalance and load rate can affect the equipment efficiency. Secondly, considering the objective of minimizing power loss, an optimization dispatch strategy with constraints of three-phase imbalance and the optimal economic operation area is proposed to obtain the dispatch power commands for the F-SOP. Furthermore, an improved peer-to-peer control for F-SOP is proposed to ensure the conduct of the optimization dispatch strategy and enhance stability performance of system. Finally, the effectiveness and feasibility of the proposed comprehensive control strategy are validated by the simulations and experiments. The results show that comprehensive control of lightly/heavily loaded operation and three-phase imbalance in the ISLDN can significantly reduce daily power loss by 62%, improving system operation reliability and economy.
S

SunView 深度解读

该F-SOP综合控制策略对阳光电源ST系列储能变流器及PowerTitan系统具有重要应用价值。文章提出的四桥臂拓扑与三相不平衡治理技术可直接应用于阳光电源储能PCS产品,提升其在分布式光伏大量接入场景下的电能质量调节能力。所提优化调度方法与改进对等控制策略可融入iSolarCloud平台,实现储能系统经济运行优化,日均损耗降低62%的效果对提升ST系列产品竞争力意义显著。该技术还可拓展至充电桩产品线,解决单相充电桩接入导致的三相不平衡问题,为阳光电源构建配网侧柔性互联解决方案提供技术储备。