逆变器开路故障对永磁同步电机多物理量的影响
Influence of Inverter Open Circuit Fault on Multiple Physical Quantities in the PMSM
| 作者 | Haoyue Tang · Weili Li · Zhigang Wu |
| 期刊 | IEEE Transactions on Power Electronics |
| 出版日期 | 2023年1月 |
| 技术分类 | 可靠性与测试 |
| 技术标签 | 故障诊断 可靠性分析 功率模块 IGBT |
| 相关度评分 | ★★★★ 4.0 / 5.0 |
| 关键词 | 逆变器 开路故障 PMSM 故障诊断 功率晶体管 可靠性 驱动系统 |
语言:
中文摘要
驱动系统故障多发生于逆变器功率管。相比短路故障,开路故障隐蔽性强且不易察觉,虽不会瞬间损毁系统,但会导致电机进入跛行运行模式。本文研究了开路故障下电机多物理量的变化规律,旨在提升故障诊断的准确性与系统可靠性。
English Abstract
The fault of the drive system mainly occurs in the power transistor of the inverter. Compared with the short-circuit fault, open-circuit fault is not easy to perceive and accurately detect, and it will not cause instantaneously devastating damage to the system. In the case of the open-circuit fault, the motor will be in limp operation mode. At present, most of the research results are focused on f...
S
SunView 深度解读
该研究聚焦于逆变器功率器件(IGBT)的开路故障诊断,对阳光电源的组串式光伏逆变器及风电变流器产品线具有重要参考价值。在光伏与风电应用中,逆变器长期运行于复杂环境,功率模块的早期故障检测是提升系统可用性(Availability)的关键。通过分析故障下的多物理量特征,阳光电源可优化iSolarCloud平台的智能运维算法,实现故障的预判与精准定位,从而降低运维成本,提升产品在极端工况下的可靠性与安全性。