中文摘要
针对传统有限控制集模型预测控制(FCS-MPC)在T型三电平变流器中计算负担重、权重系数设计复杂的问题,本文提出了一种改进的FCS-MPC方法。该方法通过扇区优化减少计算量,并引入电容电压平衡算法,在消除权重系数的同时提升了系统整体性能。
English Abstract
Conventional finite control set model predictive control (FCS-MPC) suffers from the high computational burden and cumbersome weight factor design, especially for three-phase three-level (3P-3L) converters. In this article, an improved FCS-MPC is proposed for T-type 3P-3L converters to reduce the computational burden, eliminate the weight factor, and improve system performance. Three improvements a...
S
SunView 深度解读
该技术直接应用于阳光电源的核心产品线,特别是组串式逆变器和大型集中式逆变器中的T型三电平拓扑。通过优化FCS-MPC算法,可以显著降低DSP/FPGA的计算开销,提升控制响应速度,并有效解决中点电位平衡难题。这对于提升阳光电源逆变器在弱电网环境下的稳定性、减小滤波器体积及降低成本具有重要价值。建议研发团队在下一代高功率密度组串式逆变器中评估该算法,以进一步提升产品竞争力。