基于VSC-HVDC系统的异构PMSG风电场单机等效方法比较分析
Comparative analysis of single-machine equivalent methods for heterogeneous PMSG-based wind farm with the VSC-HVDC system
| 作者 | Qiao Li · Linlin Wu · Xiao Wang · Wenjuan Du · Haifeng Wang |
| 期刊 | Applied Energy |
| 出版日期 | 2025年1月 |
| 卷/期 | 第 380 卷 |
| 技术分类 | 风电变流技术 |
| 相关度评分 | ★★★★★ 5.0 / 5.0 |
| 关键词 | Small-signal stability of the heterogeneous PMSG-based wind farm with the VSC-HVDC system is analyzed considering dynamic differences among PMSGs. |
语言:
中文摘要
摘要 本文对四种用于简化含多台风电机组(WTG)并网风电场小信号稳定性(SSS)分析的单机等效方法进行了比较研究,重点针对采用电压源换流器高压直流输电(VSC-HVDC)系统的异构永磁同步发电机(PMSG)风电场。所比较的四种方法分别为:(1)动态聚合方法;(2)平均功率或平均控制参数方法;(3)加权平均方法;(4)覆盖定理方法。通过对比分析,揭示了这四种方法之间的联系与差异,有助于更深入理解它们的优势与局限性,具体如下:(1)当各台PMSG的动态特性不同时,动态聚合方法在评估系统小信号稳定性时可能产生误差。(2)当系统的振荡模式与PMSG输出功率或控制参数之间存在线性关系时,平均功率方法和加权平均方法在评估系统小信号稳定性方面具有较高精度;然而,当这种线性关系不成立时,这两种方法可能导致错误的小信号稳定性评估结果。(3)在各台PMSG风速不同的情况下,加权平均方法能够准确评估小信号稳定性,而采用平均风速的方法则会产生误差。(4)覆盖定理方法在小信号稳定性评估中表现出保守性。最后,通过对两种经VSC-HVDC系统接入电网的PMSG风电场拓扑结构进行仿真,验证了上述四种方法的有效性。
English Abstract
Abstract This paper presents a comparative study of four single-machine equivalent methods used to simplify the analysis of small-signal stability (SSS) in grid-connected wind farms composed of multiple wind turbine generators (WTGs), particularly focusing on heterogeneous permanent magnet synchronous generator (PMSG)-based wind farms with a VSC-HVDC system. The four methods compared are (1) the dynamic aggregation method, (2) the average power or average control parameter method, (3) the weighted average method, and (4) the covering theorem method. The comparative analysis highlights the connections and differences among those four methods that help to gain a better understanding of their strengths and limitations as follows: (1) When the dynamic characteristics of individual PMSGs are different, the dynamic aggregation method may result in errors in assessing system SSS. (2) The average power and weighted average methods are accurate in assessing the system's SSS when a linear relationship exists between the system's oscillation modes and the PMSG output or control parameters. However, both methods may give erroneous SSS assessments when this linearity does not hold. (3) The weighted average method can accurately assess SSS when wind speeds differ across PMSGs, while the average wind speed method produces errors. (4) The covering theorem method is found to be conservative in SSS assessment. Finally, the methods are validated through simulations on two PMSG-based wind farm topologies connected to the grid with a VSC-HVDC system.
S