← 返回
通过数字-模拟混合补偿抑制隧道磁阻电流传感器的温度漂移
Suppression of Temperature Drift in Tunneling Magnetoresistance Current Sensors by Digital-Analog Hybrid Compensation
| 作者 | Jieqiang Gao · Jiaming Liu · Mengmeng Guan · Xianfeng Liang · Wei Su · Shuhui Shi · Yuxin Cheng · Yang Lu · Lin Cheng · Zhongqiang Hu · Ming Liu |
| 期刊 | IEEE Transactions on Power Electronics |
| 出版日期 | 2026年4月 |
| 技术分类 | 可靠性与测试 |
| 技术标签 | 可靠性分析 功率模块 故障诊断 |
| 相关度评分 | ★★★★ 4.0 / 5.0 |
| 关键词 | 隧道磁阻 TMR 电流传感器 温度漂移 数字模拟混合补偿 检测精度 稳定性 电力电子 |
语言:
中文摘要
隧道磁阻(TMR)电流传感器因高灵敏度和低功耗备受关注,但温度漂移限制了其精度与稳定性。本文提出了一种数字-模拟混合补偿方案,有效抑制了温度漂移,实现了高精度的电流检测。
English Abstract
Tunneling magnetoresistance (TMR) current sensors have been studied extensively in recent years due to their advantages of high sensitivity and low power consumption. However, temperature drift remains a critical factor limiting their detection accuracy and stability. Here, we propose a digital-analog hybrid compensation scheme for temperature drift suppression and demonstrate a high-precision TMR...
S
SunView 深度解读
电流传感器是阳光电源组串式逆变器、PowerTitan储能系统及风电变流器中实现高精度电流采样和闭环控制的核心器件。TMR传感器相比传统霍尔传感器具有更高灵敏度,但其温漂问题是制约高功率密度产品在极端环境(如户外高温、高寒)下稳定运行的瓶颈。该数字-模拟混合补偿技术可直接应用于阳光电源的电流采样电路设计,提升iSolarCloud运维平台下各产品的监测精度,降低因传感器温漂导致的控制误差,从而提升系统整体的可靠性与并网性能。