← 返回
光伏发电技术 储能系统 ★ 5.0

光伏系统直击雷防护

Protection of Photovoltaic Systems Against Direct Lightning Strokes

作者 Behzad Kermani · Reza Shariatinasab
期刊 IEEE Transactions on Power Delivery
出版日期 2024年11月
技术分类 光伏发电技术
技术标签 储能系统
相关度评分 ★★★★★ 5.0 / 5.0
关键词 光伏系统 雷电过电压 保护系统 浪涌保护器 避雷针
语言:

中文摘要

由于光伏系统(PVs)通常安装在开阔区域,雷电涌成为设备故障的主要原因。本文在EMTP环境下建立了光伏系统的频率相关模型,分析了直击雷引起的过电压,并研究了避雷针、浪涌保护器(SPDs)、等电位连接系统(EBS)及综合接地系统对防护效果的影响。结果表明,结合SPDs、EBS及组件与逆变器间的综合接地系统可实现对逆变器的全面保护,且SPDs承受的能量低于其耐受能力。接地系统结构显著影响SPDs的性能。此外,本文提出基于滚球理论与蒙特卡洛方法的避雷针布设方案,相较传统方法更经济,能优化避雷针数量与高度。

English Abstract

As the photovoltaic systems (PVs) are installed in open areas, lightning surges constitute a significant cause of PVs equipment failure. Therefore, the study of lightning-related overvoltages in PVs is vital, and guidelines for the protection must be investigated. This paper demonstrates the frequency-dependent modeling of PVs and determines the resulting overvoltages from direct lightning strokes in the EMTP environment. By analyzing the protection equipment including the lightning rods, surge protection devices (SPDs), the equipotential bonding system (EBS), and the integrated grounding system, the appropriate protection system against lightning overvoltages is proposed. The results show that by installation of SPDs, along with EBS and an integrated grounding system between solar panels and inverters, complete protection for inverters is achieved. In this mode, the energy stress experienced by SPDs is less than their energy handling capacity. As a result, the type of ground system implementation has a significant impact on the optimal performance of the SPDs. The paper also introduces a method based on rolling sphere theory and the Monte Carlo method for designing and placing lightning rods in PVs. The presented method is cost-effective compared to the conventional methods, as it determines the appropriate number and height of the lightning rods.
S

SunView 深度解读

该直击雷防护技术对阳光电源SG系列光伏逆变器及PowerTitan大型储能系统具有重要应用价值。研究提出的SPDs与等电位连接系统(EBS)综合防护方案,可直接应用于1500V高压光伏系统的逆变器保护设计,优化阳光电源产品的雷电防护等级。基于滚球理论与蒙特卡洛方法的避雷针优化布设方案,能降低大型地面电站的防雷成本,提升系统可靠性。EMTP频率相关建模方法可集成至iSolarCloud平台,用于电站雷电风险评估与预测性维护。接地系统结构对SPDs性能的影响研究,为ST储能变流器的接地设计提供理论依据,提升设备在雷电高发区域的运行安全性。