← 返回
储能系统技术 储能系统 ★ 5.0

一种在不对称故障期间通过最小有功功率削减增强电压支持的先进控制策略

An Advanced Control Strategy for Enhancing Voltage Support With Minimum Active Power Curtailment During Asymmetrical Faults

作者 Suresh Maganti · Narayana Prasad Padhy
期刊 IEEE Transactions on Power Systems
出版日期 2024年11月
技术分类 储能系统技术
技术标签 储能系统
相关度评分 ★★★★★ 5.0 / 5.0
关键词 分布式发电机 电压支持 不对称故障 无功功率注入 有功功率削减
语言:

中文摘要

在电力系统严重电压事件(如电压暂降、暂升及其共存)期间,分布式电源需满足严格并网规范而保持并网运行。现有无功功率控制策略在应对不对称短路故障时面临健康相过电压及有功功率削减等问题。本文提出一种先进的电压支持控制策略,通过分相无功功率注入抑制健康相过电压,有效调节正序电压并抑制负序与零序电压。在生成无功电流参考值后,通过在健康相与故障相之间调整有功功率分配,最小化总有功功率削减。该策略在不同电压事件严重程度和发电工况下,经三相四桥臂并网逆变器实验平台验证,可兼顾电压支撑能力与安全电流限制。

English Abstract

During severe voltage events in power systems (sag, swell, and their co-occurrence), Distributed Generators (DGs) must remain connected for a specific duration due to stringent grid code requirements. Researchers have developed various control schemes for reactive power injection and consumption to support the voltage during this period. However, significant challenges remain, particularly during asymmetrical short-circuit faults. Over-voltage in the healthy phases of a three-phase system complicates reactive power injection. Additionally, active power curtailment is often necessary during reactive power adjustments, which needs to be minimized without compromising voltage support. This paper proposes an advanced voltage support control strategy to address the over-voltage issue during asymmetrical faults and enhance voltage support with minimum active power curtailment in compliance with voltage limits and safe current operating limits. The proposed voltage support scheme adapted phase-wise reactive power injection to address the over-voltage issue, which successfully regulates positive sequence voltage and reduces negative and zero sequence voltages. Based on the voltage event, the active power curtailment is minimized by adjusting active power delivery between healthy and faulty phases after reactive current reference generation. The proposed scheme is validated on a laboratory prototype of a grid-connected DG using a three-phase, four-leg converter under various voltage event severities and DG power generation scenarios.
S

SunView 深度解读

该不对称故障电压支持技术对阳光电源ST系列储能变流器和SG系列光伏逆变器具有重要应用价值。文章提出的分相无功功率注入策略可直接应用于三相四桥臂拓扑的储能系统,通过独立控制各相无功电流有效抑制健康相过电压,同时最小化有功功率削减,提升LVRT/HVRT期间的电网支撑能力。该技术可优化阳光电源PowerTitan大型储能系统在不对称故障工况下的并网性能,满足严格的电网规范要求。对于SG系列光伏逆变器,该策略可增强弱电网环境下的电压调节能力,减少故障期间的发电损失。建议将分相无功控制算法集成到现有GFL控制架构中,提升产品在复杂电网故障场景下的适应性和竞争力。