← 返回
一种用于双端口LLC感应加热系统的全范围ZVS综合控制策略
A Full-Range ZVS Comprehensive Control Strategy for Dual-Port LLLC Induction Heating System
| 作者 | Qixiang Yang · Fujun Ma · Zhengxiao Zhang · Junpan Wang · Gelin Huang · Rui Fan · Quanjie Li · Zhiheng Tong |
| 期刊 | IEEE Transactions on Power Electronics |
| 出版日期 | 2025年10月 |
| 技术分类 | 拓扑与电路 |
| 技术标签 | LLC谐振 双向DC-DC 功率模块 |
| 相关度评分 | ★★★ 3.0 / 5.0 |
| 关键词 | LLLC感应加热 ZVS 双移相 电力电子 环流 软开关 控制策略 |
语言:
中文摘要
本文针对高功率双端口LLC感应加热系统,提出了一种全范围零电压开关(ZVS)综合控制策略,确保系统在全功率范围内高效运行。针对重载工况,提出了新型双移相(DPS)控制策略,通过时域分析优化了循环电流曲线并扩展了ZVS范围。
English Abstract
The full-range zero voltage switching (ZVS) comprehensive control strategy is proposed for a high-power dual-port LLLC induction heating system which allows the system to operate efficiently across the entire power range. Under heavy load, a novel dual-phase-shift (DPS) control strategy is proposed in this article. Using time-domain analysis, the minimum circulating current curve and the ZVS range...
S
SunView 深度解读
该研究提出的LLLC拓扑及全范围ZVS控制策略,在电力电子变换效率优化方面具有参考价值。虽然文章侧重于感应加热领域,但其核心的软开关技术和双移相控制算法可迁移至阳光电源的储能变流器(PCS)及高频DC-DC变换模块中。特别是在PowerTitan等大型储能系统的直流侧变换环节,通过优化移相控制策略,有助于进一步降低开关损耗,提升变换效率,从而提高系统整体的功率密度和热管理性能。建议研发团队关注该拓扑在双向功率传输场景下的扩展应用。