← 返回
面向直流配电系统的多故障容错双有源桥变换器
Multiple-Fault-Tolerant Dual Active Bridge Converter for DC Distribution System
| 作者 | Haochen Shi · Huiqing Wen · Guipeng Chen · Qinglei Bu · Guanying Chu · Yinxiao Zhu |
| 期刊 | IEEE Transactions on Power Electronics |
| 出版日期 | 2021年1月 |
| 技术分类 | 拓扑与电路 |
| 技术标签 | DAB 双向DC-DC 可靠性分析 储能变流器PCS |
| 相关度评分 | ★★★★★ 5.0 / 5.0 |
| 关键词 | 直流配电系统 双有源桥(DAB) 容错 可靠性 电力变换器 直流输电 |
语言:
中文摘要
直流输电系统日益受到关注,为满足高可靠性要求,变换器需具备多故障下的不间断运行能力。然而,高容错性通常伴随着冗余电路体积庞大的问题,本文旨在解决这一矛盾,提升直流配电系统中电力电子变换器的可靠性与功率密度。
English Abstract
The dc power transmission system has been obviously attracting more research interests in recent years. In order to satisfy the high-reliability requirement of the dc power transmission system, the power converter should be able to keep uninterrupted operation after multiple unexpected faults. However, high fault-tolerant capability usually leads to the bulky redundant circuit, which increases the...
S
SunView 深度解读
该技术对阳光电源的储能系统(如PowerTitan、PowerStack)及直流微网解决方案具有重要参考价值。DAB(双有源桥)是储能变流器(PCS)的核心拓扑之一,提升其故障容错能力可显著增强储能电站的可用率和安全性。建议研发团队关注该文献中的冗余设计策略,在不显著增加体积的情况下优化PCS的模块化冗余架构,以提升产品在严苛电网环境下的可靠性,进一步巩固阳光电源在大型储能系统市场的高可靠性竞争优势。