← 返回
抑制变压器磁通饱和的三相双有源桥变换器增强型主动热平衡策略
Enhanced Active Thermal Balancing Strategy for Three-Phase Dual-Active Bridge Converter Suppressing Transformer Flux Saturation
| 作者 | Jonghun Yun · Shenghui Cui |
| 期刊 | IEEE Transactions on Power Electronics |
| 出版日期 | 2025年4月 |
| 技术分类 | 拓扑与电路 |
| 技术标签 | DAB 双向DC-DC 储能变流器PCS 功率模块 可靠性分析 |
| 相关度评分 | ★★★★★ 5.0 / 5.0 |
| 关键词 | 三相双有源桥 DAB3 三重移相 热平衡 变压器磁通饱和 功率效率 轻载工况 |
语言:
中文摘要
为提升三相双有源桥(DAB3)变换器在轻载下的效率,常采用变占空比的三重移相(TPS)调制。然而,变占空比会导致相电压不对称,进而引发相电流不对称,造成开关管热分布不均。本文提出一种主动热平衡策略,在抑制变压器磁通饱和的同时,有效解决了功率器件的热失衡问题。
English Abstract
To improve the power efficiency of three-phase dual-active bridge (DAB3) under light-load conditions, triple phase-shift (TPS) modulations with variable duty cycles have been developed. However, with variable duty cycles, asymmetric phase currents due to the asymmetric phase voltages occur. These asymmetric currents and voltages result in different switch currents, leading to thermal imbalance bet...
S
SunView 深度解读
该研究直接关联阳光电源的储能变流器(PCS)产品线,特别是PowerTitan和PowerStack系列中广泛使用的DAB拓扑。在储能系统高频化、高功率密度的趋势下,轻载效率优化与热管理是提升系统可靠性的关键。该策略通过主动热平衡技术,能够有效缓解功率模块的热应力,延长核心器件寿命,降低故障率。建议研发团队在下一代PCS控制算法中引入该热平衡逻辑,以优化多模块并联运行时的热分布,提升系统整体的长期运行可靠性。