中文摘要

针对功率器件单管关断能力测试中,一旦发生关断故障即导致器件损毁的问题,本文提出了一种基于多级阳极电压检测的鲁棒性无损测试方案。该方案能够有效评估4500V压接式器件的关断能力,在保证测试安全的同时,为器件失效机理研究提供了非破坏性的实验手段。

English Abstract

The turn-off capability test for the single cell of power devices is of great significance to both the safe operation assurance and the destruction mechanism research. However, with present techniques, the device under test is supposed to be destroyed once the turn-off fault occurs. In this article, a robust nondestructive test scheme based on the multistage anode voltage detection for 4500 V sing...
S

SunView 深度解读

该研究针对高压压接式器件(如高压IGBT)的关断能力测试,对阳光电源的集中式逆变器及大型储能系统(如PowerTitan系列)中使用的核心功率模块具有重要参考价值。高压压接器件是大型电力电子设备可靠性的基石,该无损测试方案能显著降低研发阶段的器件损耗成本,并提升对器件失效机理的深度理解。建议研发团队将其应用于高压功率模块的选型验证及可靠性评估流程中,以优化大功率变流器的安全裕度设计,提升产品在极端工况下的鲁棒性。