本文针对仅使用两个电流传感器的三相三线制并网逆变器,提出了一种能够同时诊断IGBT开路故障和电流传感器故障的新方法。该方法解决了在传感器数量受限或传感器失效场景下,无法同时实现功率器件与传感系统故障监测的技术难题,提升了逆变系统的运行可靠性。
English Abstract
This article considers fault detection in the case of a three-phase three-wire (3P3W) inverter, when only two current sensors are used to save cost or due to a faulty current sensor. With two current sensors, there is no current method addressing the diagnosis of both IGBT open-circuit (OC) faults and current sensor faults. In order to solve this problem, this article proposes a method which innov...
S
SunView 深度解读
该技术对阳光电源的组串式逆变器(如SG系列)和集中式逆变器具有重要应用价值。在追求高功率密度和成本优化的设计中,减少电流传感器数量是趋势,但会增加故障诊断难度。本文提出的双重故障诊断算法可直接集成至iSolarCloud智能运维平台或逆变器底层控制固件中,有效提升设备在复杂工况下的自诊断能力,降低运维成本。建议研发团队评估该算法的计算开销,并将其作为提升逆变器可靠性与故障容错能力的核心技术储备,特别是在无人值守的地面光伏电站场景中,能显著减少因误判导致的停机时间。