← 返回
基于平均桥臂极间电压和误差自适应阈值的并网三相电压源逆变器功率管开路故障诊断
Fast Transistor Open-Circuit Faults Diagnosis in Grid-Tied Three-Phase VSIs Based on Average Bridge Arm Pole-to-Pole Voltages and Error-Adaptive Thresholds
| 作者 | Zhan Li · Hao Ma · Zhihong Bai · Yuxi Wang · Borong Wang |
| 期刊 | IEEE Transactions on Power Electronics |
| 出版日期 | 2018年9月 |
| 技术分类 | 可靠性与测试 |
| 技术标签 | 三相逆变器 并网逆变器 故障诊断 可靠性分析 |
| 相关度评分 | ★★★★★ 5.0 / 5.0 |
| 关键词 | 三相电压源逆变器(VSI) 开路故障 故障诊断 并网逆变器 极间电压 误差自适应阈值 |
语言:
中文摘要
本文提出了一种基于模型的并网三相电压源逆变器(VSI)单管及多管开路故障诊断方法。该方法利用闭环控制中现有的信号,通过计算平均桥臂极间电压并结合误差自适应阈值进行故障判断,无需额外传感器,易于嵌入现有控制系统。
English Abstract
This paper presents a model-based method to diagnose single- and multiple-transistor open-circuit (OC) faults in grid-tied three-phase voltage-source inverters (VSIs). The method is based on calculated average bridge arm pole-to-pole (PTP) voltages and error-adaptive thresholds. Only existing signals for closed-loop control are needed; thus, this method can be easily embedded in the system without...
S
SunView 深度解读
该技术对阳光电源的核心产品线(组串式逆变器、集中式逆变器及储能变流器PCS)具有极高的应用价值。逆变器作为电力电子系统的核心,其功率器件的可靠性直接影响电站运维成本。该方法无需增加额外硬件成本,仅通过软件算法优化即可实现故障的快速定位,能显著提升iSolarCloud智能运维平台的故障预警与诊断精度,缩短运维响应时间。建议研发团队将其集成至逆变器控制固件中,以增强产品在复杂电网环境下的自诊断能力,提升系统整体可靠性。