← 返回
基于三个分流电阻的工业逆变器电流检测:局限性与解决方案
Industrial Inverter Current Sensing With Three Shunt Resistors: Limitations and Solutions
| 作者 | Zhendong Zhang · David Leggate · Takayoshi Matsuo |
| 期刊 | IEEE Transactions on Power Electronics |
| 出版日期 | 2017年6月 |
| 技术分类 | 拓扑与电路 |
| 技术标签 | 三相逆变器 功率模块 可靠性分析 组串式逆变器 |
| 相关度评分 | ★★★★★ 5.0 / 5.0 |
| 关键词 | 工业逆变器 电流检测 分流电阻 成本控制 变速驱动 电流测量 逆变器性能 |
语言:
中文摘要
随着变频驱动器技术的成熟,成本控制成为逆变器制造商的核心竞争力。本文探讨了在满足最低性能要求的前提下,通过降低传感器成本(如使用三个分流电阻)带来的技术挑战,并分析了相关的局限性及相应的优化解决方案。
English Abstract
As inverter powered variable speed drives become popular and technically mature, cost control becomes the core competence for inverter manufacturers. Under minimum performance requirement specifications, the inverter is tailored in every aspect, from the main power device to various sensors to enhance its competitiveness. This paper mainly focuses on various issues associated with the downgrade of...
S
SunView 深度解读
电流检测方案的成本优化直接关系到阳光电源组串式逆变器及工商业储能PCS产品的市场竞争力。在保证控制精度和系统稳定性的前提下,研究分流电阻(Shunt Resistor)替代霍尔传感器等高成本方案,是实现降本增效的关键路径。本文提出的局限性分析及解决方案,可为阳光电源研发团队在优化逆变器电流采样电路、提升低成本方案的抗干扰能力及动态响应性能方面提供重要参考,有助于在保持高性能的同时进一步优化产品成本结构。