← 返回
基于开关电阻电路的纹波估计与抵消方法及其在快速响应PFC预调节器中的应用
A Family of Ripple Estimation–Cancellation Methods Based on Switched-Resistor Circuits and Their Application in Fast-Response PFC Preregulator
| 作者 | K. H. Leung · K. H. Loo · Y. M. Lai |
| 期刊 | IEEE Transactions on Power Electronics |
| 出版日期 | 2017年4月 |
| 技术分类 | 拓扑与电路 |
| 技术标签 | PFC整流 PWM控制 功率模块 |
| 相关度评分 | ★★★★ 4.0 / 5.0 |
| 关键词 | PFC PFC预调节器 纹波抵消 动态响应 总谐波失真 开关电阻电路 |
语言:
中文摘要
功率因数校正(PFC)预调节器为实现低总谐波失真,通常需采用低带宽闭环控制,导致动态响应缓慢。本文提出了一系列基于开关电阻电路的纹波估计与抵消方法,旨在消除双倍工频纹波,从而在保持高功率因数的同时实现快速动态响应。
English Abstract
Power-factor-correction (PFC) preregulator commonly suffers from slow dynamic response due to the need to operate with small closed-loop bandwidth for realizing low total harmonic distortion of input current. Ripple cancellation is one of the widely adopted strategies to achieve high power factor and fast dynamic response simultaneously. The main idea is to eliminate the double-line frequency comp...
S
SunView 深度解读
该技术对阳光电源的户用及工商业光伏逆变器、电动汽车充电桩产品线具有重要参考价值。在单相PFC级中,双倍工频纹波往往限制了控制带宽,影响负载突变时的动态性能。通过引入开关电阻电路进行纹波抵消,可以在不牺牲THD性能的前提下提升系统动态响应速度,这对于提升户用储能系统(如PowerStack)中充电模块的瞬态响应能力,以及优化充电桩的电能质量控制策略具有显著的应用潜力。建议研发团队评估该方案的硬件复杂度与成本,探索其在提升功率密度和动态指标方面的工程化可行性。