← 返回
可靠性与测试 IGBT 故障诊断 可靠性分析 并网逆变器 ★ 4.0

三相四线制有源电力滤波器开路故障的电压矢量误差故障诊断

Voltage Vector Error Fault Diagnosis for Open-Circuit Faults of Three-Phase Four-Wire Active Power Filters

作者 Hui Zhang · Chuan- da Sun · Zhi-xin Li · Juan Liu · Hai-yang Cao · Xiao Zhang
期刊 IEEE Transactions on Power Electronics
出版日期 2017年3月
技术分类 可靠性与测试
技术标签 IGBT 故障诊断 可靠性分析 并网逆变器
相关度评分 ★★★★ 4.0 / 5.0
关键词 有源电力滤波器 IGBT 开路故障 故障诊断 电压矢量 三相四线制 可靠性
语言:

中文摘要

针对三相四线制有源电力滤波器(APF),本文提出了一种基于交流侧输出电压数学模型的IGBT开路故障诊断算法。该方法通过分析APF交流侧输出电压矢量与故障状态间的映射关系,实现了对功率器件故障的快速、准确检测与定位,有效提升了电力电子系统的运行安全与可靠性。

English Abstract

Detecting and locating the fault of IGBT rapidly and accurately are the keys to ensuring the security and reliability of the active power filters (APF) system. A fault diagnosis algorithm based on the mathematical model of ac side output voltages for three-phase four-wire three-leg two-level shunt APF is proposed in this paper. According to the different relationships between the APF's ac side out...
S

SunView 深度解读

该研究提出的基于电压矢量误差的故障诊断技术,对于阳光电源的组串式逆变器及储能变流器(PCS)产品具有重要的工程参考价值。在PowerTitan等大型储能系统及高功率密度逆变器中,功率模块(IGBT)的可靠性是系统长效运行的核心。该算法无需额外传感器,仅通过数学模型即可实现故障定位,有助于iSolarCloud智能运维平台实现更精准的故障预警与远程诊断,降低运维成本,提升产品在复杂电网环境下的故障自愈能力与系统可用性。