中文摘要
针对三相四线制有源电力滤波器(APF),本文提出了一种基于交流侧输出电压数学模型的IGBT开路故障诊断算法。该方法通过分析APF交流侧输出电压矢量与故障状态间的映射关系,实现了对功率器件故障的快速、准确检测与定位,有效提升了电力电子系统的运行安全与可靠性。
English Abstract
Detecting and locating the fault of IGBT rapidly and accurately are the keys to ensuring the security and reliability of the active power filters (APF) system. A fault diagnosis algorithm based on the mathematical model of ac side output voltages for three-phase four-wire three-leg two-level shunt APF is proposed in this paper. According to the different relationships between the APF's ac side out...
S
SunView 深度解读