带峰值电流保护的无电压传感器有源超级电容均衡器平均建模与性能分析
Average Modeling and Performance Analysis of Voltage Sensorless Active Supercapacitor Balancer With Peak Current Protection
| 作者 | V. Yuhimenko · G. Geula · G. Agranovich · M. Averbukh · A. Kuperman |
| 期刊 | IEEE Transactions on Power Electronics |
| 出版日期 | 2017年2月 |
| 技术分类 | 储能系统技术 |
| 技术标签 | 储能系统 储能变流器PCS 双向DC-DC PWM控制 |
| 相关度评分 | ★★★★ 4.0 / 5.0 |
| 关键词 | 超级电容器 主动均衡 双向 Buck-Boost 变换器 平均建模 无电压传感器 峰值电流保护 储能 |
语言:
中文摘要
本文提出了一种由双向Buck-Boost变换器主动均衡的双超级电容组的平均建模与分析方法。在50%占空比的开环运行下,系统可实现自然均衡,无需测量各储能单元电压。然而,即使电压存在微小偏差也会产生过大电流,本文针对该问题提出了峰值电流保护策略。
English Abstract
In this paper, average modeling and analysis of a dual-supercapacitor bank, actively balanced by a bidirectional buck-boost converter, is presented. In such a system, natural balancing is achieved when the converter is operated in open loop with 50% duty cycle, eliminating the need for measuring the voltage of each storage device. Nevertheless, excessive currents arise even for slight voltage misb...
S
SunView 深度解读
该技术对于阳光电源的储能业务(如PowerTitan、PowerStack系列)具有重要参考价值。超级电容作为一种高功率密度储能元件,常用于储能系统的瞬时功率补偿或混合储能架构中。文中提出的无电压传感器均衡方案能有效降低BMS的硬件复杂度与成本,提高系统可靠性。特别是其提出的峰值电流保护机制,对于提升阳光电源储能变流器(PCS)在处理高频功率脉冲时的安全性与稳定性具有指导意义,建议研发团队关注该拓扑在混合储能系统中的应用潜力。