← 返回
高频隔离双向DC-DC变换器在实际应用中的瞬态直流偏置与电流冲击效应
Transient DC Bias and Current Impact Effects of High-Frequency-Isolated Bidirectional DC–DC Converter in Practice
| 作者 | Biao Zhao · Qiang Song · Wenhua Liu · Yuming Zhao |
| 期刊 | IEEE Transactions on Power Electronics |
| 出版日期 | 2016年4月 |
| 技术分类 | 拓扑与电路 |
| 技术标签 | 双向DC-DC 储能变流器PCS 储能系统 功率模块 |
| 相关度评分 | ★★★★★ 5.0 / 5.0 |
| 关键词 | 高频隔离 双向DC-DC变换器 瞬态直流偏置 电流冲击 稳态移相 IBDC 电力电子 |
语言:
中文摘要
本文分析了高频隔离双向DC-DC变换器(IBDC)在实际运行中因无法严格满足稳态理论前提而产生的瞬态直流偏置及电流冲击效应。文章全面解析了稳态移相(SPS)控制策略下的瞬态特性,并探讨了相关模式及影响机制。
English Abstract
This paper presents the transient dc bias and the current impact effects of a high-frequency-isolated bidirectional dc-dc converter (IBDC) in practice because the theoretical premise in the steady process cannot be satisfied strictly in the transient process. The transient characterizations of IBDC under the steady phase-shift (SPS) strategy are analyzed comprehensively, and the corresponding mode...
S
SunView 深度解读
该研究直接关联阳光电源的核心储能业务,特别是PowerTitan和PowerStack系列中广泛采用的双向DC-DC变换器拓扑。在储能系统频繁的充放电切换及电网侧功率调度过程中,瞬态直流偏置和电流冲击是导致功率器件(如IGBT/SiC)失效和磁性元件饱和的关键因素。建议研发团队在PCS控制算法中引入针对瞬态过程的补偿策略,优化移相控制逻辑,以提升系统在复杂工况下的可靠性,减少硬件应力,从而延长储能系统全生命周期的运行寿命。