← 返回
损耗约束下对功率因数变化具有鲁棒性的三电平优化脉冲模式
Loss-Constrained Three-Level Optimized Pulse Patterns With Robustness to Power Factor Variations
| 作者 | Isavella Koukoula · Petros Karamanakos · Tobias Geyer |
| 期刊 | IEEE Transactions on Industry Applications |
| 出版日期 | 2025年2月 |
| 技术分类 | 储能系统技术 |
| 技术标签 | 储能系统 三电平 |
| 相关度评分 | ★★★★★ 5.0 / 5.0 |
| 关键词 | 三级优化脉冲模式 变换器损耗 电流谐波畸变 功率因数 结温 |
语言:
中文摘要
本文介绍了三级优化脉冲模式(OPPs)的计算方法,该方法在限制变流器损耗的同时,能保持对功率因数变化的鲁棒性。通过在优化过程中对每个半导体开关的开关损耗和导通损耗进行约束,改善了半导体损耗与电流谐波畸变之间的权衡关系。此外,为了扩大损耗约束优化问题的解空间,从而增加优化过程的自由度,放宽了传统优化脉冲模式的对称性。再者,为了增强所提出的优化脉冲模式对功率因数变化的鲁棒性,优化问题对一定范围的功率因数而非单一功率因数下的半导体损耗进行约束,从而减少了不同负载条件下的损耗变化。如所给出的数值结果所示,在较宽的工作点范围内,最坏情况下的损耗以及最坏情况下的结温都有所降低。
English Abstract
This paper presents the computation of three-level optimized pulse patterns (OPPs) that limit the converter losses while maintaining robustness against power factor variations. By constraining the switching and conduction losses of each semiconductor switch in the optimization process the trade-off between semiconductor losses and current harmonic distortions is improved. Moreover, to expand the solution space of the loss-constrained optimization problem, and thus increase the degrees of freedom in the optimization process, the symmetry properties of conventional OPPs are relaxed. Furthermore, to enhance the robustness of the proposed OPPs to changes in the power factor, the optimization problem constrains the semiconductor losses over a range of power factors rather than a single one, thereby reducing loss variation under different load conditions. As a result, the worst-case losses, and therefore the worst-case junction temperature, are reduced over a wide range of operating points, as shown with the presented numerical results.
S
SunView 深度解读
该损耗约束三电平OPP技术对阳光电源ST系列储能变流器和PowerTitan大型储能系统具有重要应用价值。通过多目标优化框架联合最小化THD和开关损耗,可直接提升三电平拓扑变流器的效率和电能质量。其对功率因数变化的鲁棒性设计,特别适用于储能系统充放电工况频繁切换场景,能有效降低SiC功率模块的热应力和损耗波动。该方法可与阳光电源现有MPPT算法和GFM控制技术协同,优化脉冲模式在线切换策略,提升系统在电网支撑、调频调峰等复杂工况下的可靠性与适应性,为iSolarCloud平台的智能诊断提供损耗预测模型支持。