← 返回

基于ICRLS和扰动滑模观测器的未知参数条件下并网三相逆变器多开关开路故障诊断

Multiple Open-Switch Fault Diagnosis of Grid-Connected Three-Phase Inverters Under Unknown Parameter Conditions Using ICRLS and Disturbance Sliding Mode Observer

语言:

中文摘要

针对未知参数条件下并网三相逆变器开关开路(OS)故障诊断问题,提出了一种结合输入补偿递归最小二乘法(ICRLS)与离散扰动滑模观测器(DSMO)的方法。该方法通过ICRLS提高参数辨识精度,并利用DSMO实现故障的快速精准定位。

English Abstract

In addressing the issue of open-switch (OS) fault diagnosis for grid-connected three-phase inverters under unknown parameter conditions, a method combining input-compensated recursive least squares (ICRLS) and a discrete disturbance sliding mode observer (DSMO) is proposed in this article. First, an ICRLS approach is introduced, which enhances the accuracy of parameter identification by compensati...
S

SunView 深度解读

该技术对阳光电源的核心产品线(组串式及集中式光伏逆变器)具有极高的应用价值。在光伏电站长期运行中,功率器件的开路故障是影响系统可靠性的关键因素。该方法在未知参数条件下实现故障诊断,无需依赖精确的系统模型,非常适合阳光电源iSolarCloud智能运维平台进行边缘侧部署。建议研发团队将其集成至逆变器底层控制算法中,通过实时监测与诊断,提前预警功率模块异常,从而降低运维成本,提升电站可用率,增强产品在复杂电网环境下的竞争优势。