本文提出了一种考虑功率因数的钳位调制技术,旨在平衡并最小化隔离直流母线双逆变器的功率损耗。双逆变器通过驱动开口绕组永磁同步电机,在相同直流电压下可输出更高电压。然而,该六桥臂结构存在损耗分布不均的问题,本文通过优化调制策略有效解决了这一挑战。
English Abstract
This article proposes a clamping modulation technique considering the power factor to balance and minimize power loss in a dual inverter with an isolated dc bus. The dual inverter, used to drive an open-end winding permanent magnet synchronous motor can output a higher voltage than a single inverter with respect to the same dc voltage. However, the dual inverter, which has six legs, has twice as m...
S
SunView 深度解读
该技术主要针对双逆变器驱动电机应用,与阳光电源现有的光伏逆变器和储能PCS产品线(主要为并网型)存在差异,但其核心的“损耗平衡与最小化调制算法”对提升阳光电源大功率组串式逆变器及PowerTitan储能变流器的效率具有参考价值。特别是针对多电平或多模块并联的拓扑结构,该文提出的钳位调制思路可用于优化功率器件的热应力分布,从而提升系统可靠性。建议研发团队关注该调制策略在多机并联系统中的损耗均衡应用,以进一步优化高功率密度产品的热设计。