← 返回

混合多馈入直流系统中系统强度对暂态过电压影响的解析评估

Analytically Assessing the Effect of Strength on Temporary Overvoltage in Hybrid Multi-Infeed HVdc Systems

作者 Hao Xiao · Xianzhong Duan · Yi Zhang · Yinhong Li
期刊 IEEE Transactions on Power Electronics
出版日期 2022年3月
技术分类 系统并网技术
技术标签 弱电网并网 构网型GFM 并网逆变器 虚拟同步机VSG
相关度评分 ★★★★ 4.0 / 5.0
关键词 混合多馈入HVdc 电压源换流器 电网换相换流器 暂态过电压 系统强度 解析评估
语言:

中文摘要

本文针对包含电压源换流器(VSC)和电网换流器(LCC)的混合多馈入直流(HMIDC)系统,研究了系统强度对暂态过电压(TOV)的影响。相比于传统的耗时电磁暂态仿真方法,本文提出了一种解析评估方法,为理解系统强度与TOV之间的理论关系提供了新视角。

English Abstract

In hybrid multi-infeed HVdc (HMIDC) systems comprising both voltage-source and line-commutated converters’ inverters, the strength has a significant effect on the temporary overvoltage (TOV). However, this effect has always been assessed by the simulated approach in earlier works. It is unable to provide the sufficiently theoretical perspectives and also time-consuming as onerous electromagnetic t...
S

SunView 深度解读

该研究关注弱电网环境下多换流器并网的稳定性与暂态过电压问题,对阳光电源的组串式逆变器及大型储能系统(如PowerTitan)在复杂电网环境下的并网控制具有重要参考价值。随着新能源渗透率提升,电网强度减弱,该解析方法有助于优化阳光电源构网型(Grid-Forming)控制策略,提升设备在弱电网下的暂态电压支撑能力,降低故障期间的过电压风险,从而增强系统并网的可靠性与安全性。