← 返回

LCL型并网逆变器谐波振荡中被忽视的元凶:谐振极点抵消

An Ignored Culprit of Harmonic Oscillation in LCL-Type Grid-Connected Inverter: Resonant Pole Cancelation

作者 Yuying He · Xuehua Wang · Donghua Pan · Xinbo Ruan · Guoxing Su
期刊 IEEE Transactions on Power Electronics
出版日期 2021年12月
技术分类 系统并网技术
技术标签 光伏逆变器 并网逆变器 弱电网并网 跟网型GFL
相关度评分 ★★★★★ 5.0 / 5.0
关键词 LCL 型并网逆变器 谐振极点抵消 谐波振荡 系统稳定性 有源阻尼 电流控制
语言:

中文摘要

谐振极点抵消常用于LCL型并网逆变器的电流控制或有源阻尼中以抑制滤波器谐振。然而,其对系统稳定性的潜在影响尚未得到充分评估。本文全面研究了三种采用谐振极点抵消的典型控制方案,并揭示了其在特定条件下可能引发谐波振荡的关键发现。

English Abstract

Resonant pole cancelation is usually adopted in the current control or active damping to tackle the filter resonance in the LCL-type grid-connected inverter. However, its potential impact on the system stability has not been adequately assessed. This article provides a comprehensive investigation on three typical control schemes that utilize resonant pole cancelation. An important finding is drawn...
S

SunView 深度解读

该研究直接关联阳光电源组串式及集中式光伏逆变器的核心控制算法。在复杂电网环境下,逆变器常采用有源阻尼技术抑制LCL滤波器谐振,若控制策略中存在不当的谐振极点抵消,可能导致系统在弱电网下发生谐波振荡。建议研发团队在优化iSolarCloud智能运维平台的故障诊断算法时,将此类由控制参数引起的谐振特性纳入模型,并在逆变器固件升级中审视有源阻尼的极点配置,以提升产品在复杂电网环境下的并网稳定性和电能质量。