← 返回

用于无电网电压传感器LCL滤波逆变器的谐振扩展状态观测器优化自抗扰控制

Optimized Active Disturbance Rejection Control With Resonant Extended State Observer for Grid Voltage Sensorless LCL-Filtered Inverter

语言:

中文摘要

本文针对LCL滤波并网逆变器,提出了一种基于谐振扩展状态观测器的优化自抗扰控制(ADRC)策略。该方法在无电网电压传感器条件下,有效应对了模型不确定性、LCL谐振及非理想电网环境带来的干扰,显著提升了电流跟踪性能与系统鲁棒性。

English Abstract

A robust optimized active disturbance rejection control (ADRC) based grid voltage sensorless current controller is developed for an LCL-filtered grid-connected inverter (GCI) via a predictive control approach under various sources of disturbance, including the model uncertainties, the LCL inherent resonance phenomenon, and nonideal grid environment. Aiming to improve the sinusoidal reference track...
S

SunView 深度解读

该技术对阳光电源的核心产品线(组串式及集中式光伏逆变器)具有极高的应用价值。在当前电网环境日益复杂、弱电网接入比例提升的背景下,无传感器控制方案不仅能降低系统硬件成本、提高可靠性,还能通过ADRC算法增强逆变器在复杂电网下的抗干扰能力。建议研发团队将其应用于新一代组串式逆变器中,特别是针对弱电网场景的控制算法优化,以提升产品在复杂电网环境下的并网稳定性,进一步巩固阳光电源在并网技术领域的领先地位。