双三相内置式永磁同步电机缺相故障容错控制的计算高效解法:最大转矩与最小脉动
Computation-Efficient Solution to Open-Phase Fault Tolerant Control of Dual Three-Phase Interior PMSMs With Maximized Torque and Minimized Ripple
| 作者 | Guodong Feng · Chunyan Lai · Wenlong Li · Yu Han · Narayan C. Kar |
| 期刊 | IEEE Transactions on Power Electronics |
| 出版日期 | 2021年4月 |
| 技术分类 | 控制与算法 |
| 技术标签 | 故障诊断 PWM控制 |
| 相关度评分 | ★★★ 3.0 / 5.0 |
| 关键词 | 双三相内置式永磁同步电机 开路故障 容错控制 转矩脉动 定子电流谐波 PMSM |
语言:
中文摘要
针对双三相内置式永磁同步电机(DT-IPMSM)的缺相故障(OPF),该文提出了一种计算高效的容错控制策略。OPF会导致定子电流谐波增加,进而引发输出转矩下降及转矩脉动。本文通过优化控制算法,在实现故障后最大转矩输出的同时,有效抑制了转矩和速度脉动,提升了系统的可靠性与安全性。
English Abstract
For dual three-phase interior permanent magnet synchronous machines (DT-IPMSMs), open-phase fault (OPF) can result in significant average torque reduction and harmonics in the output torque and speed, which prevent the machines from a reliable and safe operation. Indeed, these adverse effects are mainly due to significant harmonics in the stator currents caused by OPF. This article investigates fa...
S
SunView 深度解读
该研究聚焦于多相电机驱动系统的容错控制,虽然阳光电源目前的核心业务集中在光伏逆变器和储能变流器(PCS),但该技术在风电变流器及大功率电机驱动领域具有参考价值。随着阳光电源在风电变流器市场的深入,针对多相电机或高可靠性电机驱动的容错控制算法,有助于提升风电变流器在极端工况下的运行稳定性。建议研发团队关注该算法在降低计算复杂度方面的思路,将其迁移至光伏或储能系统的功率变换器故障诊断与容错控制中,以提升系统在功率器件或传感器故障下的不间断运行能力。