本文提出了一种基于平均电流Park矢量(ACPV)的六相容错永磁同步电机(FTPMSM)功率开关开路故障诊断方法。该方法能够在正常运行及缺相/短路容错运行条件下,有效检测出故障功率开关,提高了系统的运行可靠性。
English Abstract
In this article, a new power switch open-circuit fault diagnosis approach is proposed for the six-phase fault-tolerant permanent magnet synchronous motor (FTPMSM) system based on average current Park's vector (ACPV), which can detect the fault power switch for the FTPMSM system in both normal and phase open-circuit/short-circuit fault-tolerant operation conditions. To detect the power switch open-...
S
SunView 深度解读
该研究聚焦于多相电机驱动系统的故障诊断,虽然阳光电源目前的核心业务集中在光伏逆变器、储能PCS及风电变流器,而非直接的六相电机驱动,但其提出的基于平均电流Park矢量的故障诊断逻辑具有通用参考价值。对于阳光电源的风电变流器及大功率储能PCS产品,功率器件的开路故障诊断是提升系统可靠性(Reliability)的关键。建议研发团队借鉴该文的ACPV诊断思路,优化现有逆变器及变流器在复杂工况下的故障自愈与保护算法,以进一步提升产品在极端环境下的可用性与运维效率。