← 返回
基于虚拟过零检测与三次谐波电流分段注入的半控型开口绕组永磁同步发电机性能提升研究
Performance Improvement of Semicontrolled Open-Winding PMSGs Based on Virtual Zero-Crossing Detection and Segment Injection of Third-Order Harmonic Current
| 作者 | Zhanfeng Song · Siyu Hu · Yun Yu · Fengjiao Zhou |
| 期刊 | IEEE Transactions on Power Electronics |
| 出版日期 | 2019年12月 |
| 技术分类 | 风电变流技术 |
| 技术标签 | PWM控制 三相逆变器 功率模块 |
| 相关度评分 | ★★★ 3.0 / 5.0 |
| 关键词 | 开绕组永磁同步发电机 (PMSG) 半控型 零功率因数角 电流钳位 三次谐波注入 虚拟过零检测 |
语言:
中文摘要
本文针对共直流母线半控型开口绕组永磁同步发电机(OW-PMSG)在非零功率因数角(PFA)下存在的电流钳位问题进行了研究。通过提出虚拟过零检测与三次谐波电流分段注入策略,有效改善了系统的控制性能,解决了传统控制方案在特定工况下的电流畸变与控制失效问题。
English Abstract
The semicontrolled open-winding permanent magnet synchronous generators (OW-PMSGs) with a common dc bus system have received more attention in recent years due to its advantages of reduced cost and simpler power supply. Good control performances could be achieved under the zero power factor angle (PFA). However, current clamping problem is normally presented under non-zero PFA condition, resulting...
S
SunView 深度解读
该研究聚焦于开口绕组永磁同步发电机的控制优化,主要应用于风电变流器领域。虽然阳光电源目前风电变流器产品线以主流拓扑为主,但该文提出的谐波注入与过零检测技术对于提升变流器在复杂工况下的电流质量和控制精度具有参考价值。建议研发团队关注此类先进调制策略,以优化风电变流器在低风速或弱电网环境下的输出性能,提升系统整体效率与可靠性。