中文摘要
本文针对多相交错并联变换器,提出了一种基于状态观测器残差时域分析的开路故障诊断方法。该方法利用交错并联结构的冗余特性,在不损失纹波抑制性能的前提下,实现故障的快速识别与定位,对于提升电力电子系统在连续运行工况下的容错能力具有重要意义。
English Abstract
Fault-tolerance capability is a critical matter in power conversion systems that require continuous operation. Multiphase converters provide an inherent redundancy that gives them fault-tolerant capability. In addition, the interleaved operation of these converters provides them with some advantages regarding total current ripple, which otherwise would be lost under a fault condition. This issue c...
S