← 返回
基于原侧电感能量分析的两电平三相PWM升压整流器实时多开路故障诊断
Primary Source Inductive Energy Analysis Based Real-Time Multiple Open-Circuit Fault Diagnosis in Two-Level Three-Phase PWM Boost Rectifier
| 作者 | Feng Wu · Jin Zhao · Yang Liu · Dehong Zhou · Hui Luo |
| 期刊 | IEEE Transactions on Power Electronics |
| 出版日期 | 2018年4月 |
| 技术分类 | 可靠性与测试 |
| 技术标签 | 故障诊断 可靠性分析 PFC整流 PWM控制 |
| 相关度评分 | ★★★★ 4.0 / 5.0 |
| 关键词 | 三相Boost整流器 开路故障 故障诊断 PWM控制 电力电子可靠性 电感能量分析 |
语言:
中文摘要
两电平三相Boost整流器广泛应用于工业领域。由于热循环导致的键合线脱落,功率晶体管常发生开路故障,引起输出波动和电流谐波。本文提出了一种针对单路及多路开路故障的实时、鲁棒诊断方法,通过分析原侧电感能量变化实现故障定位,有效提升了系统的运行可靠性。
English Abstract
Two-level three-phase boost rectifiers are widely used in industrial applications due to their superior performance. According to the survey reports, the transistors often suffer from open-circuit failures due to the lifting of bonding wires caused by thermic cycling, resulting in output fluctuation and current harmonics. This paper proposes a real-time, robust fault diagnosis method for single an...
S
SunView 深度解读