通过优化开关模式实现全负载范围内ZVS的高效率电流型双有源桥DC-DC变换器
High-Efficiency Current-Fed Dual Active Bridge DC–DC Converter With ZVS Achievement Throughout Full Range of Load Using Optimized Switching Patterns
| 作者 | Deshang Sha · Xiao Wang · Deliang Chen |
| 期刊 | IEEE Transactions on Power Electronics |
| 出版日期 | 2018年2月 |
| 技术分类 | 拓扑与电路 |
| 技术标签 | DAB 双向DC-DC 储能变流器PCS PWM控制 |
| 相关度评分 | ★★★★★ 5.0 / 5.0 |
| 关键词 | 电流型双有源桥 DC-DC变换器 ZVS 开关模式 双向 效率 PWM控制 移相 |
语言:
中文摘要
针对电流型双有源桥(CF-DAB)双向DC-DC变换器,本文总结了所有可能的开关模式,并提出了一种基于占空比和移相角优化的控制策略。该策略旨在实现全负载范围内的零电压开关(ZVS),从而显著提升变换效率,解决传统DAB在轻载下效率下降的问题。
English Abstract
For current-fed dual active bridge bidirectional dc-dc converters, all the possible switching patterns are summarized in view of the combinations of both side pulse-width modulation duty cycles and phase-shift angle. A control strategy is proposed for the current-fed dual active bridge converter to operate with the optimized patterns. The equivalent duty cycle of the secondary side is smaller than...
S
SunView 深度解读
该技术对阳光电源的储能业务(如PowerTitan、PowerStack系列及ST系列PCS)具有极高价值。储能变流器(PCS)的核心在于DC-DC级的高效双向功率变换,电流型DAB拓扑在高功率密度和宽电压范围应用中表现优异。通过优化开关模式实现全负载ZVS,能显著降低PCS在不同充放电工况下的开关损耗,提升系统整体转换效率,特别是在应对电网调峰调频等频繁变载场景时,有助于提升阳光电源储能产品的市场竞争力和能效指标。