中文摘要
针对双有源桥(DAB)变换器在轻载下采用传统双移相(DPS)控制时,因外移相角微小波动导致电流、损耗及效率剧烈变化的问题,本文提出了一种新型双移相控制策略。该方法通过引入双向内移相,有效拓宽了外移相角的操作区域,实现了轻载下的恒定功率传输,降低了浪涌电流并提升了控制稳定性。
English Abstract
To transmit constant powers particularly at light load, the isolated dual active bridge (DAB) with conventional dual-phase-shift (DPS) control exhibits large variations of currents, losses, and efficiencies if there is a small change of outer phase shift ratio, which is caused by the change of command to adjust power transmission. This is mainly because of the narrow operation region of outer phas...
S
SunView 深度解读
该技术直接应用于阳光电源的储能变流器(PCS)产品线,如PowerTitan和ST系列。DAB拓扑是实现电池侧与直流母线高效能量转换的核心电路。通过优化双移相控制策略,可以显著降低PCS在轻载或待机模式下的电流应力和损耗,提升系统全功率范围内的转换效率。此外,该方法改善的功率控制稳定性有助于提升储能系统在参与电网调频等高频响应场景下的动态性能。建议研发团队在下一代高功率密度储能变流器中引入该控制算法,以优化轻载工况下的热管理和系统可靠性。