中文摘要

本文提出了一种提高自适应储能(AES)全桥变换器效率的实用方法。传统AES变换器中耦合电感匝数比为1,导致超前桥臂与滞后桥臂峰值电流相同。通过优化匝数比,可将部分超前桥臂电流转移至滞后桥臂,从而降低峰值电流并提升整体转换效率。

English Abstract

This letter proposes a simple and practical way to improve the efficiency of an adaptive-energy-storage (AES) full bridge converter. Since the turns ratio of coupled inductor is 1 in the conventional AES converter, the leading-leg and lagging-leg have the same peak current. By modifying turns ratio of coupled inductor, part of leading-leg current can be steered to the lagging-leg; thus, the peak c...
S

SunView 深度解读

该研究直接针对储能变流器(PCS)核心拓扑的效率优化,对阳光电源的PowerTitan(液冷储能系统)及ST系列PCS产品具有重要参考价值。通过调整耦合电感匝数比来优化桥臂电流分布,可有效降低功率器件的导通损耗与峰值电流应力,从而提升整机效率并改善热管理表现。建议研发团队在下一代高功率密度储能变流器设计中,引入该拓扑优化策略,以进一步提升产品在工商业及电网侧储能市场的竞争力。