风电变流技术 故障诊断 可靠性分析 功率模块 多电平 ★ 3.0

双三相电机开路故障后电流参考生成策略的变流器损耗对比研究

Comparison of Postfault Strategies for Current Reference Generation for Dual Three-Phase Machines in Terms of Converter Losses

语言:

中文摘要

双三相电机具备固有的容错能力。现有研究多关注开路故障后的定子绕组损耗,忽略了变流器损耗。本文旨在对比不同电流参考生成策略对变流器损耗的影响,以优化故障后的系统性能与可靠性。

English Abstract

Dual three-phase machines are attractive due to advantages such as inherent fault tolerance. Several strategies for current reference generation have been proposed to improve the postfault performance under open-phase fault. However, for the development and analysis of these strategies, only the stator winding losses were considered, but not the converter ones. In fact, there are no studies so far...
S

SunView 深度解读

该研究探讨了多相电机在故障状态下的变流器损耗优化,这对阳光电源的风电变流器业务具有参考价值。随着风电向大功率、高可靠性方向发展,多相电机驱动方案的应用日益增多。该文提出的损耗分析方法可用于优化阳光电源风电变流器的控制算法,特别是在应对电机绕组开路等故障时,通过改进电流参考生成策略,能够有效降低变流器功率模块的温升,提升系统在极端工况下的可靠性与运行效率,从而增强产品在海上风电等高可靠性需求场景下的竞争力。