中文摘要

在低压直流微电网短路故障中,固态断路器(SSCB)负责快速隔离故障区域,其安全性和可靠性高度依赖于缓冲电路的过电压抑制能力。本文针对SSCB缓冲电路设计提出了优化方法,解决了传统转换器开关缓冲设计在直流断路器应用中的局限性。

English Abstract

Under a short-circuit fault in low-voltage dc microgrid, solid-state circuit breaker (SSCB) assumes the responsibility of the quick and effective isolation of the faulted area, while its own safety and reliability depends on the overvoltage suppression ability of its snubber. For SSCB snubber design, however, traditional method suited for converter switch snubber cannot be directly applied, becaus...
S

SunView 深度解读

该研究对阳光电源的储能系统(如PowerTitan、PowerStack)及直流微电网解决方案具有重要意义。随着直流侧电压等级提升,储能变流器(PCS)内部直流母线及直流侧保护面临严峻的瞬态过电压挑战。优化SSCB缓冲电路设计不仅能提升PCS在直流侧短路故障下的硬件可靠性,还能降低功率器件(如IGBT/SiC)的电压应力,延长系统寿命。建议研发团队在PCS直流侧保护方案中引入该缓冲设计优化策略,以提升产品在复杂微电网环境下的故障穿越与自我保护能力。