← 返回
无需Y电容的隔离式开关电源传导EMI抑制方案
Conducted EMI Mitigation Schemes in Isolated Switching-Mode Power Supply Without the Need of a Y-Capacitor
| 作者 | Yongjiang Bai · Xu Yang · Dan Zhang · Xinlei Li · Wenjie Chen · Weihao Hu |
| 期刊 | IEEE Transactions on Power Electronics |
| 出版日期 | 2017年4月 |
| 技术分类 | 拓扑与电路 |
| 技术标签 | 光伏逆变器 储能变流器PCS 充电桩 功率模块 |
| 相关度评分 | ★★★★★ 5.0 / 5.0 |
| 关键词 | 传导EMI 开关电源 Y电容 漏电流 共模噪声 EMI抑制 |
语言:
中文摘要
传统隔离式开关电源利用Y电容为共模EMI信号提供低阻抗回路,但这会导致漏电流问题,威胁人身安全。本文提出了一种无需Y电容的传导EMI抑制方案,旨在解决隔离式AC-DC变换器中的漏电流限制与电磁兼容性之间的矛盾。
English Abstract
In order to construct a low-impedance loop for common-mode electromagnetic interference (EMI) signals, traditional method is to use Y-capacitors as filtering components. However, in the commonly used isolated ac-dc switching-mode power supplies (SMPS), the Y-capacitors branch also behaves as a terrible leakage current loop. For the safety of human beings, this leakage current is not allowed in com...
S
SunView 深度解读
该技术对阳光电源的核心产品线具有极高的应用价值。在户用光伏逆变器、充电桩及储能PCS中,漏电流(Leakage Current)是安规认证的关键指标,尤其在医疗或特定工业场景下限制严格。通过采用无需Y电容的EMI抑制方案,不仅能有效降低漏电流,还能优化系统结构,减少高压电容带来的失效风险。建议研发团队在下一代高功率密度组串式逆变器及便携式储能产品中评估该拓扑,以提升产品的安规合规性及电磁兼容性能,同时降低物料成本。