← 返回
开关谐波对移相PWM级联H桥STATCOM电容电压平衡的影响
Impact of Switching Harmonics on Capacitor Cells Balancing in Phase-Shifted PWM-Based Cascaded H-Bridge STATCOM
| 作者 | Ehsan Behrouzian · Massimo Bongiorno · Remus Teodorescu |
| 期刊 | IEEE Transactions on Power Electronics |
| 出版日期 | 2017年1月 |
| 技术分类 | 拓扑与电路 |
| 技术标签 | 多电平 PWM控制 功率模块 并网逆变器 |
| 相关度评分 | ★★★★ 4.0 / 5.0 |
| 关键词 | 级联H桥 STATCOM 移相PWM 开关谐波 电容电压平衡 配电 多电平变换器 |
语言:
中文摘要
本文研究了基于移相PWM的级联H桥STATCOM中,开关谐波对各单元瞬时功率分配的影响。通过分析高、低开关频率下电压与电流谐波的相互作用,揭示了其对电容电压平衡的影响机制,为优化多电平变换器的控制策略提供了理论依据。
English Abstract
The purpose of this paper is to investigate the impact of switching harmonics on the instantaneous power distribution in the cells of a cascaded H-bridge-based STATCOM when using phase-shifted pulse width modulation. The case of high- and low-switching frequency for the converter cells is investigated and the interaction between voltage and current harmonics is analyzed. It is shown that in both c...
S
SunView 深度解读