← 返回
应用于主动磁悬浮轴承的三电平半桥中点钳位拓扑零共模电压调制策略
Zero Common-Mode Voltage Modulation Strategy for Three-Level Half-Bridge Neutral-Point-Clamped Topology Applied to Active Magnetic Bearings
| 作者 | Jianfu Ding · Dong Jiang · Yixuan Shuai · Mingqu Zhou · Yihua Chen · Qing Wan |
| 期刊 | IEEE Transactions on Power Electronics |
| 出版日期 | 预计 2026年6月 |
| 技术分类 | 拓扑与电路 |
| 技术标签 | 三电平 多电平 PWM控制 功率模块 |
| 相关度评分 | ★★★ 3.0 / 5.0 |
| 关键词 | 主动磁轴承 三电平 NPC 共模电压 调制策略 功率变换器 寄生电容电流 EMI 抑制 |
语言:
中文摘要
主动磁悬浮轴承(AMB)是高速旋转机械的关键技术。随着功率等级提升,直流母线电压和电流增加,导致共模电压波动和寄生电容电流增大,引发功率与信号间的耦合干扰。本文提出一种零共模电压调制策略,旨在优化三电平半桥中点钳位(NPC)拓扑的性能,抑制电磁干扰。
English Abstract
Active magnetic bearing (AMB) systems serve as a key enabling technology for high-speed rotating machinery. As power ratings continue to rise, the dc-link voltage, phase current, and physical dimensions of the power converter and cabling also increase, which results in larger common-mode voltage swings and parasitic capacitive currents. Consequently, power–signal coupling issues, especially common...
S
SunView 深度解读
该研究关注三电平NPC拓扑的共模电压抑制,这对阳光电源的组串式逆变器及大功率储能变流器(如PowerTitan系列)具有参考价值。在光伏和储能系统中,随着电压等级向1500V甚至更高演进,共模电流导致的漏电流及电磁兼容(EMC)问题日益突出。该调制策略可优化逆变器输出质量,减少对电网及周边信号设备的干扰。建议研发团队关注该零共模调制方法在多电平拓扑中的应用,以提升产品在高频开关下的电磁兼容性能,优化系统整体可靠性。