本文提出了一种系统化方法,通过集成开关电容变换器(SCC)与谐振变换器(RC)来推导非隔离直流变压器(NDCX)拓扑。核心思路是将SCC中的电容支路替换为由谐振电容、谐振电感及高频变压器组成的谐振支路,从而实现高效的直流电压变换。
English Abstract
Systematic approaches are proposed for the derivation of nonisolated dc transformer (NDCX) topologies based on integration of switched-capacitor converters (SCC) and resonant converters (RC). The first method for NDCX topology construction is to replace the capacitor branch in an SCC with a resonant branch, which is composed of resonant capacitor, a resonant inductor, and a high-frequency transfor...
S
SunView 深度解读
该研究提出的非隔离直流变压器拓扑推导方法,对阳光电源的电力电子研发具有重要参考价值。特别是在PowerTitan和PowerStack等储能系统(PCS)中,高效的DC-DC变换级是提升系统功率密度和转换效率的关键。通过引入谐振技术,可以有效降低开关损耗,提升变换器在宽电压范围下的工作效率。建议研发团队关注该拓扑在双向DC-DC变换器中的应用潜力,以进一步优化储能变流器的体积与热管理性能,提升产品在工商业及电网侧储能市场的竞争力。