双三相永磁同步电机缺相故障下的转速扩展最大转矩电压比容错控制
Speed Extended Maximum Torque per Voltage Fault-Tolerant Control of Dual Three-Phase PMSMs Under Open-Phase Fault
| 作者 | Yuting Lu · Zhe Tong · Chunyan Lai · Beichen Ding · Guodong Feng |
| 期刊 | IEEE Transactions on Power Electronics |
| 出版日期 | 2025年9月 |
| 技术分类 | 控制与算法 |
| 技术标签 | 故障诊断 PWM控制 可靠性分析 |
| 相关度评分 | ★★★ 3.0 / 5.0 |
| 关键词 | 双三相永磁同步电机 开路故障 容错控制 最大转矩电压比 峰值相电压 调速范围扩展 |
语言:
中文摘要
针对双三相永磁同步电机在缺相故障下,因故障电流谐波导致峰值相电压(PPV)升高、限制电机最高转速的问题,本文提出了一种新型容错控制策略。该方法通过优化电流参考值,在保证电机运行的同时,有效降低了峰值相电压,从而显著扩展了电机的调速范围,提升了系统在故障状态下的运行可靠性。
English Abstract
For dual three-phase permanent magnet synchronous machines under open-phase fault, the peak phase voltages (PPVs) are significantly larger than that under healthy condition due to the harmonics in the postfault currents, which can greatly limit the maximum attainable speed of the motor. However, this has not been addressed in existing fault-tolerant controls (FTCs). This article presents a novel m...
S
SunView 深度解读
该研究聚焦于多相电机驱动系统的容错控制,虽然阳光电源目前的核心业务集中在光伏逆变器、储能PCS及风电变流器,但其核心控制算法(如故障诊断、容错控制、电压利用率优化)与公司风电变流器及未来可能涉及的高功率密度电机驱动技术具有底层技术同源性。对于风电变流器产品线,该容错控制策略可提升发电机在极端工况下的可靠性;对于储能PCS,其对电压利用率的优化思路可为提升功率模块的负载能力提供参考。建议研发团队关注该类算法在提升电力电子变换器可靠性方面的应用潜力。