← 返回
不平衡电网下并联分数阶并网变换器的低复杂度且低保守性Ostrowski稳定性判据
Low-Complexity and Less-Conservativeness Ostrowski Stability Criterion for Parallel Fractional Grid-Connected Converters Under Unbalanced Grid
| 作者 | Bo Long · Wandi Yang · JieFeng Hu · Jose Rodriguez · Kil To Chong |
| 期刊 | IEEE Transactions on Power Electronics |
| 出版日期 | 2024年9月 |
| 技术分类 | 系统并网技术 |
| 技术标签 | 三电平 并网逆变器 弱电网并网 组串式逆变器 |
| 相关度评分 | ★★★★★ 5.0 / 5.0 |
| 关键词 | 三电平 T 型变换器 LCL 滤波器 分数阶模型 并网变换器 不平衡电网 稳定性判据 |
语言:
中文摘要
本文针对带有LCL滤波器的三电平T型变换器(3LT2C),指出分数阶模型在描述物理LCL-3LT2C变换器静态和动态行为上比整数阶模型更精确。针对不平衡电网下的并联系统,提出了一种低复杂度且低保守性的Ostrowski稳定性判据,以优化并网控制性能。
English Abstract
Three-level T-type converter (3LT2C) with LCL filter have been widely used in renewable energy power generation system. Recent articles have shown that, due to the fractional characteristics of the inductance and capacitance of the LCL filter, the fractional-order model has higher accuracy than integer-order model in describing the static- and dynamic-behaviors of the physical LCL-3LT2C converter....
S
SunView 深度解读
该研究直接关联阳光电源的核心产品线——组串式逆变器及大型地面电站并网技术。阳光电源的组串式逆变器广泛采用三电平拓扑及LCL滤波器,在弱电网或电网不平衡工况下,系统的稳定性是并网控制的核心挑战。本文提出的分数阶建模方法能更精准地捕捉高频谐振特性,有助于优化控制算法,提升逆变器在复杂电网环境下的鲁棒性。建议研发团队将该稳定性判据集成至iSolarCloud智能运维平台的仿真模型中,或应用于新一代组串式逆变器的控制固件开发,以进一步提升产品在弱电网下的并网适应能力。