一种用于混合MMC直流故障下抑制桥臂过流和子模块过压的反向偏置电压控制方法
A Reverse-Biased Voltage Controlling Method for Mitigating Arm Overcurrent and Submodule Overvoltage in Hybrid MMCs During DC Faults
| 作者 | Xiongfeng Fang · Gen Li · Cheng Wang · Lei Li |
| 期刊 | IEEE Transactions on Power Electronics |
| 出版日期 | 2023年12月 |
| 技术分类 | 拓扑与电路 |
| 技术标签 | 多电平 故障诊断 并网逆变器 储能变流器PCS |
| 相关度评分 | ★★★★ 4.0 / 5.0 |
| 关键词 | 混合MMC 直流故障 桥臂过流 子模块过压 反向偏置电压 故障清除 电力电子 |
语言:
中文摘要
针对混合模块化多电平变换器(MMC),封锁子模块是清除直流故障的常用方法,但会导致桥臂反向偏置电压失控,引发桥臂过流及子模块过压。本文提出一种反向偏置电压控制方法,通过优化控制策略,有效缓解故障期间的电流集中问题,提升系统在直流故障下的可靠性。
English Abstract
Blocking all submodules (SMs) of the hybrid modular multilevel converter is a simple way to clear dc fault currents. However, each arm's reverse-biased voltage (RBV) is uncontrolled in this method. In this case, the dc fault current will concentrate into two of the six arms. Thus, the maximum arm current will increase to the fault current in the dc line, which will lead to arm overcurrent. Moreove...