← 返回
低电容StatCom的电容状态监测方法:一种利用固有二次谐波振荡的在线方法
Capacitor Condition Monitoring Method for Low-Capacitance StatComs: An Online Approach Using the Inherent Second-Harmonic Oscillations
| 作者 | Ezequiel Rodriguez Ramos · Ramon Leyva · Qingxiang Liu · Glen G. Farivar · Josep Pou |
| 期刊 | IEEE Transactions on Power Electronics |
| 出版日期 | 2023年9月 |
| 技术分类 | 可靠性与测试 |
| 技术标签 | 储能变流器PCS 可靠性分析 故障诊断 多电平 |
| 相关度评分 | ★★★★ 4.0 / 5.0 |
| 关键词 | StatCom 级联H桥 电容状态监测 电容估计 ESR估计 二倍频振荡 可靠性 |
语言:
中文摘要
级联H桥低电容静止同步补偿器(StatCom)通过减小电容尺寸以降低成本,但会导致电容电压出现较大波动。电容的老化(电容值减小或等效串联电阻ESR增加)会严重影响StatCom的性能与安全性。本文提出了一种利用固有二次谐波振荡的在线监测方法,实现对电容状态的实时评估。
English Abstract
The cascaded H-bridge low-capacitance static compensator (StatCom) deliberately reduces the capacitor size while allowing large oscillations in capacitor voltages. When a capacitor deteriorates, its capacitance decreases or/and its equivalent series resistance (ESR) increases, compromising StatCom performance and safety. For this reason, the condition monitoring of the capacitors is important to s...
S
SunView 深度解读
该技术对阳光电源的PowerTitan及ST系列储能变流器(PCS)具有重要参考价值。随着储能系统向高功率密度发展,薄膜电容的减容设计是趋势,但其寿命管理是行业痛点。该方法无需额外硬件,仅通过算法提取二次谐波即可实现电容健康状态(SOH)监测,可集成至iSolarCloud平台,实现储能系统的预防性维护,提前预警电容失效风险,显著提升电站运维的智能化水平和系统可靠性。