← 返回

用于直流分量抑制的带低通滤波器和频率锁定环的离散多重二阶广义积分器

Discrete Multiple Second-Order Generalized Integrator With Low-Pass Filters and Frequency-Locked Loop for DC Rejection

作者 Haoyang Zheng · Zeng Liu · Ronghui An · Jinjun Liu · Kaiwen Feng · Yiming Tu
期刊 IEEE Transactions on Power Electronics
出版日期 2022年10月
技术分类 系统并网技术
技术标签 并网逆变器 跟网型GFL 弱电网并网 PWM控制
相关度评分 ★★★★★ 5.0 / 5.0
关键词 MSOGI 直流偏置 电网同步 频率锁定环 低通滤波器 数字实现 信号提取
语言:

中文摘要

多重二阶广义积分器(MSOGI)广泛应用于电网同步与信号提取,但常受直流偏置问题困扰。本文提出了一种在数字实现中消除正交通道直流偏移的方法,通过引入低通滤波器(LPF)和频率锁定环(FLL),有效提升了离散域下的信号检测精度与系统稳定性。

English Abstract

The multiple second-order generalized integrator (MSOGI), which is composed of parallel second-order generalized integrators (SOGI), is widely used in grid synchronization and signal extraction, and it usually suffers from dc offset issue. In continuous domain, low-pass filter (LPF) can be added to SOGI to eliminate the dc offset in its quadrature channel. However, in digital implementation, direc...
S

SunView 深度解读

该技术直接优化了并网逆变器的锁相环(PLL)算法,对于阳光电源的组串式和集中式光伏逆变器至关重要。在弱电网环境下,直流分量抑制能力直接影响电流谐波质量和并网稳定性。通过引入该离散域优化算法,可提升iSolarCloud平台下逆变器在复杂电网条件下的鲁棒性,减少因直流偏移导致的保护误动作。建议研发团队将其集成至新一代DSP控制固件中,以提升产品在弱电网接入场景下的竞争优势。