← 返回
混合多馈入高压直流输电系统中强度对换相失败影响的解析量化
Analytically Quantifying the Impact of Strength on Commutation Failure in Hybrid Multi-Infeed HVdc Systems
| 作者 | Hao Xiao · Xianzhong Duan · Yi Zhang · Tongkun Lan · Yinhong Li |
| 期刊 | IEEE Transactions on Power Electronics |
| 出版日期 | 2022年5月 |
| 技术分类 | 系统并网技术 |
| 技术标签 | 弱电网并网 并网逆变器 构网型GFM 跟网型GFL |
| 相关度评分 | ★★★★ 4.0 / 5.0 |
| 关键词 | 混合多馈入直流输电 换相失败 系统强度 电压源换流器 电网换相换流器 解析量化 |
语言:
中文摘要
本文针对包含电压源换流器(VSC)和电网换流器(LCC)的混合多馈入高压直流(HMIDC)系统,提出了一种解析方法来量化系统强度对换相失败(CF)的影响。相较于传统的仿真方法,该解析模型能更高效、更深入地从理论层面揭示系统强度与换相失败之间的内在联系。
English Abstract
The strength has a large impact on the commutation failure (CF) in hybrid multi-infeed HVdc (HMIDC) systems including both voltage-source converters and line-commutated converters. However, this impact has always been quantified by the simulation-based method in earlier works, which is very time-consuming and cannot lend the exhaustively theoretical perspective. Thus, in this letter, the mathemati...
S
SunView 深度解读
该研究对于阳光电源的组串式逆变器及大型储能系统(如PowerTitan)在弱电网环境下的并网稳定性具有重要参考价值。随着新能源渗透率提升,电网强度波动加剧,该解析方法可辅助优化逆变器及PCS的控制策略,特别是针对构网型(GFM)技术的参数整定,能有效提升系统在复杂电网环境下的抗扰动能力,降低因电网故障导致的脱网风险,为iSolarCloud智能运维平台提供更精准的电网适应性评估模型。