← 返回
一种基于IGCT的新型混合电网换相换流器以缓解高压直流输电中的换相失败
A Novel Hybrid Line Commutated Converter Based on IGCT to Mitigate Commutation Failure for High-Power HVdc Application
| 作者 | Chaoqun Xu · Zhanqing Yu · Biao Zhao · Zhengyu Chen · Zongze Wang · Chunpin Ren · Rong Zeng |
| 期刊 | IEEE Transactions on Power Electronics |
| 出版日期 | 2022年5月 |
| 技术分类 | 拓扑与电路 |
| 技术标签 | 功率模块 可靠性分析 弱电网并网 |
| 相关度评分 | ★★★ 3.0 / 5.0 |
| 关键词 | 电网换相换流器 IGCT 换相失败 HVdc 混合换流器 电力电子 |
语言:
中文摘要
为降低基于电网换相换流器(LCC)的高压直流输电系统换相失败概率,本文提出了一种基于集成门极换流晶闸管(IGCT)的新型混合LCC拓扑。该方案通过部分替换传统晶闸管,利用反向阻断IGCT的双向耐压能力,有效提升了换流器在弱电网下的运行稳定性与抗干扰能力。
English Abstract
In order to effectively reduce the commutation failure probability of the line commutated converter (LCC) based high-voltage direct current transmission system, a new hybrid LCC based on integrated gate commutated thyristor (IGCT) is proposed in this letter. In the proposed converter, a part of the thyristors is replaced by IGCTs. Reverse blocking IGCT is capable of withstanding bidirectional volt...
S
SunView 深度解读