本文提出了一种辅助电流控制技术,旨在改善Buck变换器的负载瞬态响应。该技术通过采用软开关技术提高了辅助变换器的效率,并给出了变换过程中输出电容电荷平衡的设计准则。仿真结果表明,该方法有效提升了输出电压的动态性能。
English Abstract
An auxiliary current control is proposed herein to improve the load transient response of the buck converter. The proposed technique increases the efficiency of the auxiliary converter by employing soft switching. The design guidelines for achieving a capacitor charge balance for the output capacitor during the transition are also presented. The simulation results revealed that the output voltage ...
S
SunView 深度解读
该研究聚焦于Buck变换器的瞬态响应优化,这对阳光电源的户用光伏逆变器及储能PCS中的DC-DC变换级具有参考价值。在光储一体化系统中,负载突变(如大功率家电启动)对输出电压稳定性要求极高。该文提出的软开关辅助电流控制技术,有助于提升变换器在轻载与重载切换时的动态响应速度,同时通过软开关降低损耗,符合阳光电源追求高效率与高功率密度的产品设计方向。建议研发团队关注该拓扑在提升系统动态性能与电磁兼容性方面的潜力,可应用于新一代户用储能系统的DC-DC模块优化。