瑞士整流器(SR)利用三相解折叠电路将交流电压转换为两个时变正电压。通过应用移相全桥拓扑,该方案在无需大容量解耦电容的情况下,实现了功率因数校正(PFC)和稳定的直流输出,并实现了软开关(ZVS)及低次谐波抑制。
English Abstract
The Swiss-type rectifier (SR) uses a three-phase unfolder circuit to convert the ac voltage into two time-varying positive voltages. The power factor correction of ac sides and the stable dc voltage output can be realized by using two dc-dc topologies without any bulky decoupling capacitors. By applying the phase-shifted full-bridge topology into the dc structure, both the soft-switching and the h...
S
SunView 深度解读
该技术对阳光电源的储能变流器(PCS)及工商业光伏逆变器具有重要参考价值。瑞士整流器架构通过取消大容量解耦电容,有助于提升功率密度并延长系统寿命,这与PowerTitan等储能产品追求高集成度、长寿命的趋势高度契合。全桥移相ZVS技术可显著降低开关损耗,提升系统效率。建议研发团队关注该拓扑在三相高功率密度整流场景下的应用,特别是在优化PCS前端PFC级效率及减小体积方面,可作为下一代高效率、紧凑型储能变流器的技术储备。