← 返回
拓扑与电路 DC-DC变换器 故障诊断 可靠性分析 ★ 4.0

考虑开关故障的浮动交错式DC-DC升压变换器自抗扰电压控制

Active Disturbance Rejection Voltage Control of a Floating Interleaved DC–DC Boost Converter With Switch Fault Consideration

语言:

中文摘要

为提升浮动交错式DC-DC升压变换器(FIBC)的鲁棒性并应对开关故障不确定性,本文提出了一种自适应自抗扰控制(ADRC)策略。通过数字滤波器实时获取系统输入控制增益,实现对控制器参数b0的自适应调节,有效提升了系统在故障工况下的控制性能。

English Abstract

To enhance the robustness and to deal with the switch fault uncertainty of a floating interleaved dc-dc boost converter (FIBC), an adaptive active disturbance rejection control (ADRC) is proposed in this paper. In particular, the controller parameter b0 is adapted by obtaining approximately the system input control gain b in real time, based on the output duty cycles via digital filters. Compared ...
S

SunView 深度解读

该技术对阳光电源的组串式逆变器及储能PCS产品具有重要参考价值。FIBC拓扑常用于光伏升压及储能双向变换环节,引入自抗扰控制(ADRC)能显著提升系统在复杂工况下的动态响应能力。特别是针对开关故障的容错控制研究,可直接优化阳光电源PowerTitan等储能系统的可靠性设计,通过算法层面的鲁棒性增强,降低硬件故障导致的停机风险,提升产品全生命周期的运维稳定性。