← 返回
混合交直流微电网中对称CLLC型直流变压器的三步开关频率选择准则
Three-Step Switching Frequency Selection Criteria for Symmetrical CLLC-Type DC Transformer in Hybrid AC/DC Microgrid
| 作者 | Jingjing Huang · Xin Zhang |
| 期刊 | IEEE Transactions on Power Electronics |
| 出版日期 | 2019年10月 |
| 技术分类 | 拓扑与电路 |
| 技术标签 | 双向DC-DC 储能变流器PCS 微电网 LLC谐振 |
| 相关度评分 | ★★★★★ 5.0 / 5.0 |
| 关键词 | CLLC型直流变压器 交直流混合微电网 谐振频率 功率传输 开关频率选择 DC-DC变换器 |
语言:
中文摘要
在混合交直流微电网中,对称CLLC型直流变压器(CLLC-DCT)常采用简单的开环控制以确保功率传输。然而,该拓扑存在多个谐振频率且特性各异,且实际谐振频率会随温度等因素波动。本文提出了一种三步开关频率选择准则,旨在优化CLLC-DCT在不同工况下的运行性能与效率。
English Abstract
In a hybrid ac/dc microgrid, the symmetrical CLLC-type dc transformer (CLLC-DCT) generally operates at the resonant frequency with the simple and low-cost semi-regulated open-loop scheme to ensure the power transmission (PT). However, more than one resonant frequency may exist, and they feature different characteristics for DCT. Meanwhile, the practical resonant frequencies are varying with temper...
S
SunView 深度解读
该研究直接关联阳光电源的储能系统(如PowerTitan、PowerStack系列)及直流微电网解决方案。CLLC拓扑是实现高效率双向DC-DC变换的核心技术,对于提升储能变流器(PCS)的功率密度和效率至关重要。文章提出的频率选择准则能有效解决实际运行中因温度波动导致的谐振偏移问题,有助于优化PCS在宽电压范围下的软开关特性,提升系统可靠性。建议研发团队将其应用于新一代高压储能变流器的控制算法优化中,以提升产品在复杂电网环境下的适应能力。